Anechoic Chamber

Product category

    Interface 1: Size

      Interface 2: Size

        Power rating max.

          Frequency min.

            Frequency max.

              0.8 mm male connector EZ-20-LA soldered DC-167 GHz product photo
              0.8 mm male connector EZ-20-LA soldered DC-167 GHz
              BN:
              530863
              Frequency range:
              DC to 167 GHz
              Return loss min.:
              21 dB @ DC to 40 GHz
              18 dB @ 40 to 90 GHz
              15 dB @ 90 to 120 GHz
              12 dB @ 120 to 167 GHz
              Flexible dielectric waveguide set R 740 60-90 GHz 2x500 mm EasySnake product photo
              Flexible dielectric waveguide set R 740 60-90 GHz 2x500 mm EasySnake
              BN:
              533659C0215
              Return loss min.:
              16 dB
              Lifetime:
              100,000 flex cycles
              Operating temperature:
              0 to +30 °C
              Flexible dielectric waveguide set R 1.4k 110-170 GHz 1x600 mm EasySnake product photo
              Flexible dielectric waveguide set R 1.4k 110-170 GHz 1x600 mm EasySnake
              BN:
              533662C0119
              Return loss min.:
              13 dB
              Lifetime:
              100,000 flex cycles
              Operating temperature:
              0 to +30 °C
              3.5 mm male to 3.5 mm female precision adapter product photo
              3.5 mm male to 3.5 mm female precision adapter
              BN:
              533769C0001
              Frequency range:
              DC to 32 GHz
              Return loss min.:
              34 dB @ DC to 4 GHz
              30 dB @ 4 to 26.5 GHz
              26 dB @ 26.5 to 32 GHz
              PCB launch connector R 740 (WR 12) 60-90 GHz thickness up to 2.2 mm product photo
              PCB launch connector R 740 (WR 12) 60-90 GHz thickness up to 2.2 mm
              BN:
              533412C0001
              Operating temperature:
              -40 to +85 °C
              Flexible dielectric waveguide set R 1.4k 110-170 GHz 2x600 mm EasySnake product photo
              Flexible dielectric waveguide set R 1.4k 110-170 GHz 2x600 mm EasySnake
              BN:
              533662C0219
              Return loss min.:
              13 dB
              Lifetime:
              100,000 flex cycles
              Operating temperature:
              0 to +30 °C
              Flexible dielectric waveguide set R 740 60-90 GHz 1x500 mm EasySnake product photo
              Flexible dielectric waveguide set R 740 60-90 GHz 1x500 mm EasySnake
              BN:
              533659C0115
              Return loss min.:
              16 dB
              Lifetime:
              100,000 flex cycles
              Operating temperature:
              0 to +30 °C
              Flexible dielectric waveguide set R 900 75-110 GHz 1x600 mm EasySnake product photo
              Flexible dielectric waveguide set R 900 75-110 GHz 1x600 mm EasySnake
              BN:
              533660C0119
              Return loss min.:
              16 dB
              Lifetime:
              100,000 flex cycles
              Operating temperature:
              0 to +30 °C
              R 900 to 1.35 mm female 75-90 GHz precision adapter product photo
              R 900 to 1.35 mm female 75-90 GHz precision adapter
              BN:
              533124
              Frequency range:
              75 to 90 GHz
              Return loss min.:
              16 dB
              R 620 to RUG-1.0 mm female 50-75 GHz precision adapter product photo
              R 620 to RUG-1.0 mm female 50-75 GHz precision adapter
              BN:
              533143
              Frequency range:
              50 to 75 GHz
              Return loss min.:
              16 dB

              RF Components for Test and Measurement in Anechoic Chambers for Mobile Communication

              Radio frequency testing of mobile communication and professional mobile radio equipment in the open-air environment is influenced by a large number of disturbing and unwanted signals in the atmosphere such as radar, broadcast and many other radio frequency emissions. This effect can cause misleading test results.

              The best solution is to put these mobile communication devices in isolated rooms, shielded boxes or special RF test chambers with low-reflection surfaces, so-called anechoic chambers. Anechoic chambers are common for test scenarios of antennas and components for mobile communication and PMR/TETRA.

              It is also recommended to place little to none interfering RF measurement devices in the room itself to avoid any further effects. However you have to transmit the RF signals in and out the shielded RF chamber without having large losses. For mobile communication SPINNER offers an entire portfolio of highly suitable, up-to-date measurement equipment to achieve the best signal transmission between the measurement device and the components under test (DUT) in an RF diagnostic chamber.

              Particularly with vector network analyzers (VNA), it is essential to use high-precision connectors, terminations and adapters for PMR and mobile communication. The same statement applies to calibration kits and mechanical accessories. SPINNER has established new, extremely high standards of precision for the mobile communication testing equipment.

              Recently Viewed