Surge Protectors

Interface size

    Interface gender

      Frequency min.

        Frequency max.

          Surge protector type

            12 Items
            • «
            • 1
            • »
            Surge protector 7-16 male 7-16 female bulkhead DC-2700 MHz for gas discharge arrestor product photo
            Surge protector 7-16 male 7-16 female bulkhead DC-2700 MHz for gas discharge arrestor
            BN:
            194284
            VSWR, max.:
            1.06 @ DC to 1.0 GHz
            1.20 @ 1.0 to 2.5 GHz
            1.40 @ 2.5 to 2.7 GHz
            Insertion loss max.:
            0.1 dB
            Surge protector 4.3-10 male screw to 4.3-10 female 430-850 W 694-2700 MHz hybrid product photo
            Surge protector 4.3-10 male screw to 4.3-10 female 430-850 W 694-2700 MHz hybrid
            BN:
            432900
            VSWR, max.:
            1.20 @ 694 to 725 MHz
            1.15 @ 725 to 2675 MHz
            1.20 @ 2675 to 2700 MHz
            Insertion loss max.:
            0.1 dB
            Passive intermodulation (IM3), max.:
            -160 dBc
            Surge protector 4.3-10 female to 4.3-10 female 430-850 W 694-2700 MHz hybrid product photo
            Surge protector 4.3-10 female to 4.3-10 female 430-850 W 694-2700 MHz hybrid
            BN:
            432901
            VSWR, max.:
            1.20 @ 694 to 725 MHz
            1.15 @ 725 to 2675 MHz
            1.20 @ 2675 to 2700 MHz
            Insertion loss max.:
            0.1 dB
            Passive intermodulation (IM3), max.:
            -160 dBc
            Surge protector 7-16 male to 7-16 female 1600-3200 W 698-2700 MHz hybrid product photo
            Surge protector 7-16 male to 7-16 female 1600-3200 W 698-2700 MHz hybrid
            BN:
            756468
            VSWR, max.:
            1.50 @ 698 to 800 MHz
            1.14 @ 800 to 850 MHz
            1.11 @ 850 to 2450 MHz
            1.14 @ 2450 to 2500 MHz
            1.50 @ 2500 to 2700 MHz
            Insertion loss max.:
            0.4 dB @ 698 to 800 MHz
            0.1 dB @ 800 to 2500 MHz
            0.4 dB @ 2500 to 2700 MHz
            Passive intermodulation (IM3), max.:
            -165 dBc
            Surge protector 7-16 male to 7-16 female 600-950 W 800-2170 MHz quarter wavelength stub product photo
            Surge protector 7-16 male to 7-16 female 600-950 W 800-2170 MHz quarter wavelength stub
            BN:
            756473
            VSWR, max.:
            1.10
            Insertion loss max.:
            0.1 dB
            Passive intermodulation (IM3), max.:
            -160 dBc
            Surge protector 7-16 male to 7-16 female 3000 W 380-512 MHz quarter wavelength stub product photo
            Surge protector 7-16 male to 7-16 female 3000 W 380-512 MHz quarter wavelength stub
            BN:
            766419
            VSWR, max.:
            1.20 @ 380 to 430 MHz
            1.22 @ 380 to 512 MHz
            Insertion loss max.:
            0.1 dB
            Surge protector 4.3-10 male screw to 4.3-10 female bulkhead 850 W 698-3800 MHz quarter wavelength stub with DC break product photo
            Surge protector 4.3-10 male screw to 4.3-10 female bulkhead 850 W 698-3800 MHz quarter wavelength stub with DC break
            BN:
            766440
            VSWR, max.:
            1.40 @ 698 to 800 MHz
            1.30 @ 800 to 850 MHz
            1.20 @ 850 to 3800 MHz
            Insertion loss max.:
            0.1 dB
            Passive intermodulation (IM3), max.:
            -165 dBc
            Surge protector 7-16 female to 7-16 female bulkhead 1300-2700 W 678-2700 MHz hybrid product photo
            Surge protector 7-16 female to 7-16 female bulkhead 1300-2700 W 678-2700 MHz hybrid
            BN:
            766471
            VSWR, max.:
            1.25 @ 678 to 698 MHz
            1.20 @ 698 to 725 MHz
            1.15 @ 725 to 2675 MHz
            1.20 @ 2675 to 2700 MHz
            Insertion loss max.:
            0.1 dB
            Passive intermodulation (IM3), max.:
            -160 dBc
            Surge protector 7-16 male to 7-16 female 1300-2700 W 678-2700 MHz hybrid product photo
            Surge protector 7-16 male to 7-16 female 1300-2700 W 678-2700 MHz hybrid
            BN:
            766475
            VSWR, max.:
            1.25 @ 678 to 698 MHz
            1.20 @ 698 to 725 MHz
            1.15 @ 725 to 2675 MHz
            1.20 @ 2675 to 2700 MHz
            Insertion loss max.:
            0.1 dB
            Passive intermodulation (IM3), max.:
            -160 dBc
            Surge protector 7-16 female 7-16 female DC-2700 MHz for gas discharge arrestor product photo
            Surge protector 7-16 female 7-16 female DC-2700 MHz for gas discharge arrestor
            BN:
            920480
            VSWR, max.:
            1.06 @ DC to 1.0 GHz
            1.20 @ 1.0 to 2.5 GHz
            1.40 @ 2.5 to 2.7 GHz
            Insertion loss max.:
            0.1 dB
            Surge protector N male to N female DC-2700 MHz for gas discharge arrestor product photo
            Surge protector N male to N female DC-2700 MHz for gas discharge arrestor
            BN:
            950880
            VSWR, max.:
            1.06 @ DC to 1.0 GHz
            1.20 @ 1.0 to 2.5 GHz
            1.40 @ 2.5 to 2.7 GHz
            Insertion loss max.:
            0.1 dB
            Surge protector N female N female bulkhead DC-2700 MHz for gas discharge arrestor product photo
            Surge protector N female N female bulkhead DC-2700 MHz for gas discharge arrestor
            BN:
            950888
            VSWR, max.:
            1.06 @ DC to 1.0 GHz
            1.20 @ 1.0 to 2.5 GHz
            1.40 @ 2.5 to 2.7 GHz
            Insertion loss max.:
            0.1 dB
            12 Items
            • «
            • 1
            • »

            Surge Protectors protect your transmission lines

            Mobile communication systems are constantly at risk of being adversely affected or damaged by overvoltages, induced DC voltages etc. Protective devices such as surge protectors and DC Breaks are used to offset these external influences. Both have the job of safeguarding the connected system without interfering with its operation. Products from SPINNER are excellent suited for protecting mobile communication installations, due to their low PIM, attenuation and reflection. Our protective devices are available with a choice of 7-16, 4.3-10 or N connector.

            Overvoltages are typically the result of electromagnetic induction because of events such as lightning strikes. For different applications, SPINNER offers surge protectors with gas discharge tube, λ/4 short-circuit loop or a combination of both in a hybrid surge protector.

            A reliable protection against surges is given only by a proper installation and regular maintenance depending on the protector type. The maintenance intervals depend mainly upon the number and the strength of the impulse current impacts.

            Surge Protectors with gas discharge arrestor can be used for all applications in the frequency range of 0 to 2.5 GHz. The RF power rating is limited by the spark over voltage of the discharge arrestor.

            Type II - with quarter wavelength stub. This kind of surge protector is suitable for applications with single or multiple combined mobile communication bands (e. g. GSM900, GSM1800 and UMTS). DC transmission via the coaxial ports is not possible with this type. The stub can be orthogonal to or folded into the axis of the main line (In line design).

            Type III – with quarter wavelength stub and DC Break. The internally separated inner conductor improves the protection effect and extends the bandwidth from 698 MHz up to 2700 MHz. Therefore, the whole frequency range of the most common mobile communication bands and W-LAN data transmission accord. to IEEE 802.11b/g or Bluetooth can be covered by one protector only. On the other hand, the DC break type is asymmetric, i.e. there are defined ports for the antenna and for the protected transceiver side.

            Type IV - with quarter wavelength line and gas discharge arrestor. This surge protector design combines the advantages of both protecting techniques (DC transmission and low intermodulation). Therefore, it is also called a hybrid design. The bandwidth is 0 to 10 MHz and 698 MHz to 2700 MHz. Hence these surge protectors are suitable for DC and low frequency (LF) transmission and can also be used to transmit control signals (e.g. according to AISG) of antenna amplifiers and/or remote-controlled antennas.

            If you can’t find your surge protector according to your specifications online, please contact our sales team with the specification needed per email or select one of the displayed products for a Quote Request and add your special requirements in the comment field of the form before submitting.