Coaxial 2-way switch (DPDT) 790 W DC-5 GHz 24 VDC N female with 3 RF-levels product photo Front View L
For a larger view click on the picture.

Coaxial 2-way switch (DPDT) 790 W DC-5 GHz 24 VDC N female with 3 RF-levels

512716
Not available This product is discontinued.

RF characteristics

Number of interfaces:
12
Interface type:
N female (50 Ω) per IEC 61169-4
Interface direction:
straight
Version:
with 3 RF-levels
Frequency range:
DC to 5 GHz
Average power rating:
790 W @ DC to 1 GHz (at -10 to +45 °C ambient temperature)
560 W @ 1 to 2 GHz (at -10 to +45 °C ambient temperature)
450 W @ 2 to 3 GHz (at -10 to +45 °C ambient temperature)
350 W @ 3 to 5 GHz (at -10 to +45 °C ambient temperature) 1)
Peak voltage:
3.0 kV 1)
VSWR, max.:
1.03 @ DC to 1 GHz
1.13 @ 1 to 3 GHz
1.22 @ 3 to 5 GHz
Insertion loss max.:
0.04 dB @ DC to 2 GHz
0.06 dB @ 2 to 5 GHz
Isolation, min.:
75 dB @ DC to 1 GHz
60 dB @ 1 to 3 GHz
50 dB @ 3 to 5 GHz

Electrical characteristics

Switch type:
built-in
Switch actuator type:
solenoid drive, latching, self cutoff
Operating connector designation:
J1
Operating connection:
37 pole male connector according to DIN 41652 / IEC 807-2
Operating voltage:
22 to 31 V DC
Operating current, max.:
1.9 A 2)
Operating current, typ.:
2.4 A
Operating standby current, max.:
35.0 mA
Operating fuses:
3 A (The switch must be externally fused by time-delay)
Control connector designation:
J1
Control connection:
37 pole male connector according to DIN 41652 / IEC 807-2
Control voltage rating remark:
12 V DC for signal 1
2 V DC for signal 2
Controlling either with signal 1 or signal 2; it's not allowed to use both control signals at the same time
Control current, max.:
1 mA (for signal 1)
Control current, typ.:
-1 mA (for signal 2)
Control fuses:
The circuit must be externally limited to 0.5 A
Interlock connector designation:
J1
Interlock connection:
37 pole male connector according to DIN 41652 / IEC 807-2
Interlock voltage:
≥ 42.4 V ACpk
≥ 60 V DC
Interlock voltage remark:
SELV circuits according to IEC EN 60950-1
Interlock current, max.:
0.5 A
Interlock fuses:
The circuit must be externally limited to 0.5 A
Signaling connector designation:
J1
Signaling connection:
37 pole male connector according to DIN 41652 / IEC 807-2
Signaling voltage:
≥ 42.4 V ACpk
≥ 60 V DC
Signaling voltage remark:
SELV circuits according to IEC EN 60950-1
Signaling current, max.:
≥ 0.5 A
Signaling fuses:
The circuit must be externally limited to 0.5 A
Switch command hold time, min.:
0.1 s
Switching frequency, max.:
10 operations per minute

Mechanical characteristics

Lifetime:
100,000 operations
Degree of protection:
IP 40
Degree of protection remark:
connected with appropriate gasket
Protection class:
III according to IEC EN 61140
Weight, approx.:
2.0 kg

Environmental conditions

Operational conditions:
ETSI EN 300 019-1-3 V2.3.2 (2009-1) class 3.1 N
Operating temperature:
-10 to +45 °C 3)
Relative humidity, max.:
95% (condensation not allowed)
Transport conditions:
ETSI EN 300 019-1-2 V2.1.4 (2003-04) class 2.2
Transport temperature range:
-25 to +70 °C
Transport rain, condensation, icing:
not allowed
Storage conditions:
ETSI EN 300 019-1-1 V2.1.4 (2003-04) class 1.2
Storage ambient temperature:
-10 to +45 °C
Storage rain, condensation, icing:
not allowed

Further remarks

1):
Standard conditions:
• Dielectric: Dry air under standard pressure at sea level (p = 1013 hPa)
• Load VSWR, max. 1.0 (no standing wave)
• No modulation, sinusoidal carrier only
2):
At room temperature and nominal voltage 24 V DC
3):
Extended temperature range on request
Customs tariff number:
85365080

Downloads

512716-DS.pdf

Product data sheet – 512716 – 512716-DS.pdf