Coaxial 2-way plug-in switch (DPDT) 41 kW DC-860 MHz 230 VAC 29.5-68 USL-D product photo Front View L
For a larger view click on the picture.

Coaxial 2-way plug-in switch (DPDT) 41 kW DC-860 MHz 230 VAC 29.5-68 USL-D

553364

RF characteristics

Number of interfaces:
4
Interface type:
29.5-68 USL-D (50 Ω) per company standard 61774
Interface direction:
straight
Frequency range:
DC to 860 MHz
Average power rating:
41 kW @ DC to 100 MHz
27 kW @ 100 to 230 MHz
14 kW @ 230 to 860 MHz 1)
Peak voltage:
8.1 kV 1)
VSWR, max.:
1.04
Insertion loss max.:
0.1 dB
Isolation, min.:
80 dB @ DC to 230 MHz
70 dB @ 230 to 700 MHz

Electrical characteristics

Switch type:
plug-in
Switch actuator type:
motor drive, latching, self cutoff
Mains connector designation:
J2
Mains connection:
5 pole SPINNER connector BN 126920, certified according to VDE-Reg. No. B687, DIN EN 61984: 2009-11; EN 61984: 2009 2)
Mains connection system:
L, N, PE, TN-System
Operating voltage:
187 to 253 V AC
Operating AC frequency:
50/60 Hz
Operating current, typ.:
1 A 4)
Operating fuses:
2 A (The switch must be secured externally by a time-delay fuse)
Control connector designation:
J1
Control connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Control voltage rating remark:
ES1 circuits according to EN 62368-1
Control current, typ.:
12 mA at control voltage 24 V DC
Control fuses:
The circuit must be externally fused to 0.5 A
Interlock connector designation:
J1
Interlock connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Interlock voltage:
≥ 42.4 V ACpk
≥ 60 V DC
Interlock voltage remark:
ES1 circuits according to EN 62368-1
Interlock current, max.:
0.5 A
Interlock fuses:
The circuit must be externally limited to 0.5 A
Signaling connector designation:
J1
Signaling connection:
25 pole connector according to DIN 41652 / IEC 807-2 2)
Signaling voltage:
≥ 42.4 V ACpk
≥ 60 V DC
Signaling voltage remark:
ES1 circuits according to EN 62368-1
Signaling current, max.:
≥ 0.5 A
Signaling fuses:
The circuit must be externally limited to 0.5 A
Strapping plug interlock connector designation:
J3
Strapping plug interlock connection:
8 pole SPINNER connector BN 125651 3)
Strapping plug interlock voltage:
≥ 42.4 V ACpk
≥ 60 V DC
Strapping plug interlock voltage remark:
ES1 circuits according to EN 62368-1
Strapping plug interlock current, max.:
≥ 0.5 A
Strapping plug interlock fuses:
The circuit must be externally limited to 0.5 A
Switch command hold time, min.:
0.2 s
Switching frequency, max.:
10 operations per minute

Mechanical characteristics

Lifetime:
250,000 operations
Degree of protection:
IP 40
Degree of protection remark:
all interfaces terminated
Protection class:
I according to IEC EN 61140
Weight, approx.:
9.0 kg

Environmental conditions

Operational conditions:
ETSI EN 300 019-1-3 V2.3.2 (2009-1) class 3.1 N
Operating temperature:
-10 to +60 °C 5)
Relative humidity, max.:
95% (condensation not allowed)
Operating altitude, max.:
4000 m (according to IEC EN 60664-1)
Transport conditions:
ETSI EN 300 019-1-2 V2.1.4 (2003-04) class 2.2
Transport temperature range:
-25 to +70 °C
Transport rain, condensation, icing:
not allowed
Storage conditions:
ETSI EN 300 019-1-1 V2.1.4 (2003-04) class 1.2
Storage ambient temperature:
-10 to +60 °C
Storage rain, condensation, icing:
not allowed

Further remarks

1):
Standard conditions:
• Dielectric: Dry air under standard pressure at sea level (p = 1013 hPa)
• Load VSWR, max. 1.0 (no standing wave)
• No modulation, sinusoidal carrier only
2):
Suitable mating connector included
3):
Suitable SPINNER mating connector BN 539145 not in delivery!
4):
At room temperature and nominal voltage 230 V AC
5):
Extended temperature range on request
Customs tariff number:
85353010

Downloads

553364-DS.pdf

Product data sheet – 553364 – 553364-DS.pdf

M36274.pdf